On this page
Confirm the removal direction
Ask how the selected retention arrangement is dismantled and which side needs access. Identify caps, pressure plates, seals and other parts that must be removed or renewed. Include adjacent units and corner details in the review. Similar-looking elevations can use different glazing methods, so the maintenance strategy must follow the actual assembly.
Test the access route against the finished site
Check lifting positions, roof access, ground surfaces and internal circulation at the replacement location. Record restrictions caused by canopies, balustrades and fixed equipment. Assess the largest or heaviest relevant unit as well as a typical bay. Obtain a competent replacement method rather than assuming a crane can always return to the original erection position.
Keep replacement information traceable
Retain glass build-ups, dimensions, coating orientation and unit identification in the handover pack. Ask which seals and retention parts are intended to be renewed. Provide a process for ordering a matching replacement and approving any substitute. A visually similar glass unit may differ in thermal, solar, safety or appearance characteristics.
Information to agree before manufacture
- Identify glazing retention and removal direction by facade zone.
- Review access for typical and difficult replacement locations.
- Record glass dimensions, build-up and orientation.
- Confirm parts that need renewal during replacement.
- Keep lifting and temporary-protection requirements documented.
- Define approval of replacement glass or alternative materials.
A question to resolve early
Can the original installation method always be used for replacement?
No. Completed construction and occupation may remove the original access. The replacement strategy should be checked against the finished building and agreed with competent specialists.
Manufacturer reference
FWS 50 documentation describes a mullion-transom facade approach; replacement planning must follow the selected retention and junction details. Schüco: FWS 50.
This reference illustrates a manufacturer’s system approach. Confirm availability, applicable documentation and the final configuration with the project supplier.
Related technical guides
Discuss your project with Alumproof
Send your drawings, project location and required performance. We can review the information and clarify the system configuration and quotation scope.
All technical guides · Technical support for architects · Explore aluminium systems