Schüco ADS 70 HD – Aluminium doors

Schüco ADS 70 HD Aluminium Door System for professional architectural projects. Key published data include frame thermal transmittance uf (≥) 2.3 W/(m²·K); maximum height 3000 mm; maximum width 1400 mm. Final values depend on configuration.

Category: Brand:
Certified quality systems
Thermally insulated system
Reliable project delivery support

Description

Schüco ADS 70 HD Aluminium Door System

Schüco ADS 70 HD is a Schüco aluminium door system developed for professional entrance and door construction. Alumproof provides system selection, feasibility review, detailed coordination, production documentation, CNC fabrication, assembly, glazing and project logistics. The configuration is selected for the actual element sizes, architectural intent, required performance and installation conditions.

Schüco ADS 70 HD is the primary system reference used throughout this product specification.

Specified correctly, Schüco ADS 70 HD can form a clear and technically controlled part of the architectural envelope. The system is therefore reviewed against the actual drawings and performance brief before components are ordered.

Schüco ADS 70 HD Technical Data

The following values originate from the referenced Schüco product information. They may describe maximum dimensions, best values or particular tested arrangements and must not be interpreted as simultaneous performance for every element.

Frame thermal transmittance Uf (≥) 2.3 W/(m²·K)
Maximum height 3000 mm
Maximum width 1400 mm
Maximum glazing or panel thickness 52 mm
Maximum vent weight 200 kg
Area of application Residential projects, commercial projects
Air permeability Class 2
Watertightness Class 5A
Wind-load resistance Class C3
Burglar resistance Up to RC3
Impact resistance Class 1

What the Published Values Mean for the Project

The published frame thermal transmittance uf (≥) of 2.3 W/(m²·K) is a reference value for the stated Schüco arrangement, not a guaranteed whole-project result. The project calculation must include element size, glazing or infill and installation junctions.

The published maximum height of 3000 mm describes a system limit rather than an automatic design allowance. Proportions, loads, infill weight, hardware and exposure determine whether that size is feasible.

The published maximum width of 1400 mm describes a system limit rather than an automatic design allowance. Proportions, loads, infill weight, hardware and exposure determine whether that size is feasible.

The maximum glazing or panel thickness of 52 mm defines an important compatibility limit. Glass build-up, edge cover, weight, safety class, coating position and gasket selection must all be checked together.

Key Design Considerations

  • Frame thermal transmittance Uf (≥): 2.3 W/(m²·K).
  • Maximum height: 3000 mm.
  • Maximum width: 1400 mm.
  • Maximum glazing or panel thickness: 52 mm.
  • Maximum vent weight: 200 kg.
  • Area of application: Residential projects, commercial projects.
  • Air permeability: Class 2.
  • Watertightness: Class 5A.
  • Wind-load resistance: Class C3.
  • Burglar resistance: Up to RC3.
  • Impact resistance: Class 1.
  • Configuration: profiles, glazing or infill, hardware and interfaces are selected as one coordinated system.
  • Verification: final dimensions and performance are checked for the actual project arrangement.
  • Documentation: approved details are transferred into production and installation information.

Design, Performance and Application

Schüco ADS 70 HD is defined by much more than the frame profile. Opening direction, leaf size, threshold, infill, hinges, locks, closers, handles and access-control components form one operational assembly. Alumproof coordinates these elements around the intended use, whether the requirement is a residential entrance, a frequently operated commercial door or a glazed door integrated into a façade.

Door dimensions and weight must be checked against the selected hinge and hardware configuration. The choice between glass and panel infill affects thermal behaviour, stiffness and appearance. Threshold construction influences weather resistance and accessibility, while the fixing arrangement must transfer operating and wind loads into the surrounding structure without distorting the frame. These issues are resolved before machining and assembly.

Published thermal, air, water, wind, acoustic or security classifications apply to specific tested combinations of profiles, seals, infill and hardware. A change to leaf dimensions, lock preparation, threshold or glazing can alter the declared result. Alumproof therefore verifies which performance claims are relevant to the proposed door and avoids extending a classification beyond the manufacturer-approved configuration.

Interface drawings show the head, jamb and threshold zones, including membranes, insulation continuity, drainage and floor build-up. For access-controlled entrances, cable routes, lock type, door loop and power requirements are coordinated with the electrical designer. Finish, colour, visible hardware and panel geometry are reviewed together so that the final construction remains technically coherent and visually consistent.

Glazing, Infill and Interfaces

Glazing or opaque infill is selected for safety, thermal, acoustic, structural and visual requirements. The nominal capacity of a profile does not by itself confirm that a proposed glass build-up is suitable. Alumproof checks thickness, weight, edge cover, support, compatibility with gaskets and sealants, and the influence of the infill on the element hardware and frame. Where panels, back pans, membranes or insulation are included, their interfaces are documented as part of the complete construction.

Connections to concrete, steel, timber, roofing, insulation, waterproofing and internal finishes are developed around the actual opening and substrate. Particular attention is given to fixing access, edge distances, drainage paths, membrane continuity, movement, tolerances and replaceability. These details help preserve the intended performance of Schüco ADS 70 HD after the element leaves the factory.

From Drawings to Production

Schüco ADS 70 HD is most effective when design responsibilities are made explicit. Alumproof can develop the aluminium package, while structural calculations, glass design, waterproofing strategy and site interfaces are coordinated with the appropriate project specialists.

Alumproof reviews drawings, elevations, schedules and specifications before preparing production documentation. The review covers dimensions, opening logic, profile selection, component availability, machining access, hardware positions, drainage, glazing sequence, transport size and installation access. Questions that can affect cost or feasibility are raised before fabrication rather than being transferred to the construction site.

Approved profiles are cut and CNC-machined according to the production information. Assembly and glazing follow the selected system configuration, with checks appropriate to the product type and agreed quality plan. Finished elements are identified, protected and packed for coordinated delivery. Installation responsibilities, lifting conditions and site tolerances should be confirmed separately for each project.

Why Specify Schüco ADS 70 HD Through Alumproof?

Alumproof combines architectural understanding with practical aluminium fabrication. This makes it possible to compare system variants, identify dimensional or interface risks, develop buildable details and maintain a direct connection between approved drawings and production. The objective is a technically coherent result that supports the architecture and can be manufactured, transported, installed and maintained as planned.

Related Alumproof Resources

Important System Note

All technical values, classifications and dimensional limits must be verified for the final Schüco ADS 70 HD configuration. Actual performance depends on element size and proportions, selected profile variant, glazing or panel, hardware, seals, drainage, reinforcement, fixings, installation substrate and workmanship. A value published for one tested specimen or best-performing configuration must not be applied unconditionally to another construction.

Send your drawings, elevations, schedules or specification to Alumproof for a technical review and project quotation.