Schüco AOC 50 ST – Facade on steel structure

Schüco AOC 50 ST Aluminium Façade System for professional architectural projects. Key published data include frame thermal transmittance uf (≥) 0.78 W/(m²·K); minimum visible profile width 50 mm; maximum glazing or panel thickness 70 mm. Final values depend on configuration.

Category: Brand:
Certified quality systems
Thermally insulated system
Reliable project delivery support

Description

Schüco AOC 50 ST Aluminium Façade System

Schüco AOC 50 ST is a Schüco aluminium façade system developed for professional glazed façade construction. Alumproof provides system selection, feasibility review, detailed coordination, production documentation, CNC fabrication, assembly, glazing and project logistics. The configuration is selected for the actual element sizes, architectural intent, required performance and installation conditions.

Schüco AOC 50 ST is the primary system reference used throughout this product specification.

Specified correctly, Schüco AOC 50 ST can form a clear and technically controlled part of the architectural envelope. The system is therefore reviewed against the actual drawings and performance brief before components are ordered.

Schüco AOC 50 ST Technical Data

The following values originate from the referenced Schüco product information. They may describe maximum dimensions, best values or particular tested arrangements and must not be interpreted as simultaneous performance for every element.

Frame thermal transmittance Uf (≥) 0.78 W/(m²·K)
Minimum visible profile width 50 mm
Maximum glazing or panel thickness 70 mm
Maximum weight 1500 kg
Surface finishes Powder-coated, anodised or painted
Air permeability AE
Impact resistance I5/E5
Burglar resistance Up to RC3
Suitable for safety barrier loading Yes

What the Published Values Mean for the Project

The published frame thermal transmittance uf (≥) of 0.78 W/(m²·K) is a reference value for the stated Schüco arrangement, not a guaranteed whole-project result. The project calculation must include element size, glazing or infill and installation junctions.

A published minimum visible profile width of 50 mm helps the design team understand the achievable sightline. The final elevation still depends on the selected outer frame, vent, mullion, transom or interlock combination.

The maximum glazing or panel thickness of 70 mm defines an important compatibility limit. Glass build-up, edge cover, weight, safety class, coating position and gasket selection must all be checked together.

The stated maximum weight of 1500 kg is relevant only with the appropriate hardware, geometry and support conditions. Operating forces, transport and installation method may impose a lower project limit.

Key Design Considerations

  • Frame thermal transmittance Uf (≥): 0.78 W/(m²·K).
  • Minimum visible profile width: 50 mm.
  • Maximum glazing or panel thickness: 70 mm.
  • Maximum weight: 1500 kg.
  • Surface finishes: Powder-coated, anodised or painted.
  • Air permeability: AE.
  • Impact resistance: I5/E5.
  • Burglar resistance: Up to RC3.
  • Suitable for safety barrier loading: Yes.
  • Configuration: profiles, glazing or infill, hardware and interfaces are selected as one coordinated system.
  • Verification: final dimensions and performance are checked for the actual project arrangement.
  • Documentation: approved details are transferred into production and installation information.

Design, Performance and Application

Schüco AOC 50 ST is developed as an engineered grid of load-bearing profiles, pressure zones, seals, glazing supports and connections. Mullion and transom depths are selected from structural requirements rather than appearance alone. Glass dimensions, support conditions, building height, wind exposure, bay width and bracket spacing all influence the final profile and reinforcement strategy.

Façade design also requires controlled water management. External seals, pressure equalisation chambers, drainage paths and compartmentation must work continuously across mullions, transoms, corners and opening elements. Alumproof prepares project details that coordinate these functions with slab edges, parapets, roofs, plinths, adjacent cladding and internal finishes. Movement allowances are considered where the façade must accommodate structural deflection or thermal expansion.

The glazing specification is checked for thickness, build-up, edge cover, weight, safety requirements and compatibility with gaskets, setting blocks and structural bonding where applicable. Opaque infill zones may require insulation, back pans, vapour control and fire-stopping as separate project-designed layers. Opening windows, doors and solar shading are integrated only where the selected Schüco combination provides a technically compatible interface.

Performance data shown for a façade platform are based on defined test arrangements and do not automatically describe every project elevation. Air permeability, watertightness, wind-load resistance, thermal behaviour, acoustics and burglar resistance depend on grid dimensions, profile selection, joints, infill and workmanship. The project application of Schüco AOC 50 ST must therefore be assessed as a complete envelope assembly.

Glazing, Infill and Interfaces

Glazing or opaque infill is selected for safety, thermal, acoustic, structural and visual requirements. The nominal capacity of a profile does not by itself confirm that a proposed glass build-up is suitable. Alumproof checks thickness, weight, edge cover, support, compatibility with gaskets and sealants, and the influence of the infill on the element hardware and frame. Where panels, back pans, membranes or insulation are included, their interfaces are documented as part of the complete construction.

Connections to concrete, steel, timber, roofing, insulation, waterproofing and internal finishes are developed around the actual opening and substrate. Particular attention is given to fixing access, edge distances, drainage paths, membrane continuity, movement, tolerances and replaceability. These details help preserve the intended performance of Schüco AOC 50 ST after the element leaves the factory.

From Drawings to Production

Schüco AOC 50 ST is most effective when design responsibilities are made explicit. Alumproof can develop the aluminium package, while structural calculations, glass design, waterproofing strategy and site interfaces are coordinated with the appropriate project specialists.

Alumproof reviews drawings, elevations, schedules and specifications before preparing production documentation. The review covers dimensions, opening logic, profile selection, component availability, machining access, hardware positions, drainage, glazing sequence, transport size and installation access. Questions that can affect cost or feasibility are raised before fabrication rather than being transferred to the construction site.

Approved profiles are cut and CNC-machined according to the production information. Assembly and glazing follow the selected system configuration, with checks appropriate to the product type and agreed quality plan. Finished elements are identified, protected and packed for coordinated delivery. Installation responsibilities, lifting conditions and site tolerances should be confirmed separately for each project.

Why Specify Schüco AOC 50 ST Through Alumproof?

Alumproof combines architectural understanding with practical aluminium fabrication. This makes it possible to compare system variants, identify dimensional or interface risks, develop buildable details and maintain a direct connection between approved drawings and production. The objective is a technically coherent result that supports the architecture and can be manufactured, transported, installed and maintained as planned.

Related Alumproof Resources

Important System Note

All technical values, classifications and dimensional limits must be verified for the final Schüco AOC 50 ST configuration. Actual performance depends on element size and proportions, selected profile variant, glazing or panel, hardware, seals, drainage, reinforcement, fixings, installation substrate and workmanship. A value published for one tested specimen or best-performing configuration must not be applied unconditionally to another construction.

Send your drawings, elevations, schedules or specification to Alumproof for a technical review and project quotation.