Schüco AWS 90 BS.SI+ – Concealed-sash windows

Schüco AWS 90 BS.SI+ Aluminium Window System for professional architectural projects. Key published data include minimum visible profile width 77 mm; frame thermal transmittance uf (≥) 0.8 W/(m²·K); maximum glazing or panel thickness 58 mm. Final values depend on configuration.

Category: Brand:
Certified quality systems
Thermally insulated system
Reliable project delivery support

Description

Schüco AWS 90 BS.SI+ Aluminium Window System

Schüco AWS 90 BS.SI+ is a Schüco aluminium window system developed for professional window construction. Alumproof provides system selection, feasibility review, detailed coordination, production documentation, CNC fabrication, assembly, glazing and project logistics. The configuration is selected for the actual element sizes, architectural intent, required performance and installation conditions.

Schüco AWS 90 BS.SI+ is the primary system reference used throughout this product specification.

The practical quality of Schüco AWS 90 BS.SI+ is decided during coordination: system limits, visual proportions, hardware, glazing, drainage and fixings must support the same design intent. Alumproof connects those decisions directly with fabrication.

Schüco AWS 90 BS.SI+ Technical Data

The following values originate from the referenced Schüco product information. They may describe maximum dimensions, best values or particular tested arrangements and must not be interpreted as simultaneous performance for every element.

Minimum visible profile width 77 mm
Frame thermal transmittance Uf (≥) 0.8 W/(m²·K)
Maximum glazing or panel thickness 58 mm
Maximum vent width 1700 mm
Maximum vent height 2400 mm
Maximum sound reduction index Rwp 49 dB
Air permeability Class 4
Watertightness Class 9A
Burglar resistance Up to RC3
Wind-load resistance Class C4 / B4
CE marking Yes

What the Published Values Mean for the Project

A published minimum visible profile width of 77 mm helps the design team understand the achievable sightline. The final elevation still depends on the selected outer frame, vent, mullion, transom or interlock combination.

The published frame thermal transmittance uf (≥) of 0.8 W/(m²·K) is a reference value for the stated Schüco arrangement, not a guaranteed whole-project result. The project calculation must include element size, glazing or infill and installation junctions.

The maximum glazing or panel thickness of 58 mm defines an important compatibility limit. Glass build-up, edge cover, weight, safety class, coating position and gasket selection must all be checked together.

The published maximum vent width of 1700 mm describes a system limit rather than an automatic design allowance. Proportions, loads, infill weight, hardware and exposure determine whether that size is feasible.

Key Design Considerations

  • Minimum visible profile width: 77 mm.
  • Frame thermal transmittance Uf (≥): 0.8 W/(m²·K).
  • Maximum glazing or panel thickness: 58 mm.
  • Maximum vent width: 1700 mm.
  • Maximum vent height: 2400 mm.
  • Maximum sound reduction index Rwp: 49 dB.
  • Air permeability: Class 4.
  • Watertightness: Class 9A.
  • Burglar resistance: Up to RC3.
  • Wind-load resistance: Class C4 / B4.
  • CE marking: Yes.
  • Configuration: profiles, glazing or infill, hardware and interfaces are selected as one coordinated system.
  • Verification: final dimensions and performance are checked for the actual project arrangement.
  • Documentation: approved details are transferred into production and installation information.

Design, Performance and Application

Schüco AWS 90 BS.SI+ is developed as part of the coordinated Schüco aluminium platform. For the designer, this means that profile geometry, glazing, hardware, seals and drainage are considered as one construction rather than as unrelated components. The system can be assessed for punched openings, ribbon windows and façade-integrated units. Opening type, vent proportions and handle position must be selected together because they influence usability, structural behaviour and the permissible weight of the glazed vent.

During specification, the visual width of the outer frame, vent and mullion should be coordinated with the elevation grid and interior finishes. Glass thickness and edge cover must suit the selected profiles, while the glass weight must remain within the capacity of the fittings. Where large vents are required, Alumproof checks width-to-height proportions, hardware loads, operating forces and the position of packers and fixing points before production drawings are released.

Thermal results cannot be assigned from the profile alone. The final window value depends on frame geometry, element size, glass centre-pane performance, spacer, glazing ratio, opening type and installation junction. Airtightness, watertightness, wind-load resistance and acoustic performance likewise refer to defined tested specimens. Project calculations and specifications therefore need to identify the complete reference construction rather than quote only the most favourable catalogue value.

The perimeter connection is developed to maintain continuity between the window, insulation, air barrier, waterproofing and internal finish. Sill drainage, membranes, subframes, brackets and tolerances are coordinated with the wall build-up. This approach is especially important for low-energy buildings, exposed façades and replacement projects where the existing opening may not provide a regular or sufficiently strong fixing substrate.

Glazing, Infill and Interfaces

Glazing or opaque infill is selected for safety, thermal, acoustic, structural and visual requirements. The nominal capacity of a profile does not by itself confirm that a proposed glass build-up is suitable. Alumproof checks thickness, weight, edge cover, support, compatibility with gaskets and sealants, and the influence of the infill on the element hardware and frame. Where panels, back pans, membranes or insulation are included, their interfaces are documented as part of the complete construction.

Connections to concrete, steel, timber, roofing, insulation, waterproofing and internal finishes are developed around the actual opening and substrate. Particular attention is given to fixing access, edge distances, drainage paths, membrane continuity, movement, tolerances and replaceability. These details help preserve the intended performance of Schüco AWS 90 BS.SI+ after the element leaves the factory.

From Drawings to Production

Before Schüco AWS 90 BS.SI+ reaches production, the key decisions are visible in coordinated drawings: element references, profile zones, infill, opening direction, drainage, fixings and interfaces. This reduces ambiguity for procurement, CNC machining, assembly and site installation.

Alumproof reviews drawings, elevations, schedules and specifications before preparing production documentation. The review covers dimensions, opening logic, profile selection, component availability, machining access, hardware positions, drainage, glazing sequence, transport size and installation access. Questions that can affect cost or feasibility are raised before fabrication rather than being transferred to the construction site.

Approved profiles are cut and CNC-machined according to the production information. Assembly and glazing follow the selected system configuration, with checks appropriate to the product type and agreed quality plan. Finished elements are identified, protected and packed for coordinated delivery. Installation responsibilities, lifting conditions and site tolerances should be confirmed separately for each project.

Why Specify Schüco AWS 90 BS.SI+ Through Alumproof?

Alumproof combines architectural understanding with practical aluminium fabrication. This makes it possible to compare system variants, identify dimensional or interface risks, develop buildable details and maintain a direct connection between approved drawings and production. The objective is a technically coherent result that supports the architecture and can be manufactured, transported, installed and maintained as planned.

Related Alumproof Resources

Important System Note

All technical values, classifications and dimensional limits must be verified for the final Schüco AWS 90 BS.SI+ configuration. Actual performance depends on element size and proportions, selected profile variant, glazing or panel, hardware, seals, drainage, reinforcement, fixings, installation substrate and workmanship. A value published for one tested specimen or best-performing configuration must not be applied unconditionally to another construction.

Send your drawings, elevations, schedules or specification to Alumproof for a technical review and project quotation.