Schüco AS PD 39.NI – Panoramic sliding doors

Schüco AS PD 39.NI Aluminium Sliding Door System for professional architectural projects. Key published data include minimum vent height 2000 mm; maximum vent height 4500 mm; minimum vent width 1000 mm. Final values depend on configuration.

Category: Brand:
Certified quality systems
Non-thermally insulated system
Reliable project delivery support

Description

Schüco AS PD 39.NI Aluminium Sliding Door System

Schüco AS PD 39.NI is a Schüco aluminium sliding door system developed for professional large-format sliding and folding construction. Alumproof provides system selection, feasibility review, detailed coordination, production documentation, CNC fabrication, assembly, glazing and project logistics. The configuration is selected for the actual element sizes, architectural intent, required performance and installation conditions.

Schüco AS PD 39.NI is the primary system reference used throughout this product specification.

Schüco AS PD 39.NI gives the design team a defined Schüco platform from which a project-specific aluminium sliding door system can be developed. The final solution is shaped by the elevation, required function, exposure and the details at every perimeter connection.

Schüco AS PD 39.NI Technical Data

The following values originate from the referenced Schüco product information. They may describe maximum dimensions, best values or particular tested arrangements and must not be interpreted as simultaneous performance for every element.

Minimum vent height 2000 mm
Maximum vent height 4500 mm
Minimum vent width 1000 mm
Maximum vent width 3000 mm
Visible vent width 25 mm
Minimum interlock face width 25 mm
Minimum system basic depth 107 mm
Watertightness Class 7A, 300 Pa
Operating type Manual

What the Published Values Mean for the Project

The published minimum vent height of 2000 mm describes a system limit rather than an automatic design allowance. Proportions, loads, infill weight, hardware and exposure determine whether that size is feasible.

The published maximum vent height of 4500 mm describes a system limit rather than an automatic design allowance. Proportions, loads, infill weight, hardware and exposure determine whether that size is feasible.

The published minimum vent width of 1000 mm describes a system limit rather than an automatic design allowance. Proportions, loads, infill weight, hardware and exposure determine whether that size is feasible.

The published maximum vent width of 3000 mm describes a system limit rather than an automatic design allowance. Proportions, loads, infill weight, hardware and exposure determine whether that size is feasible.

Key Design Considerations

  • Minimum vent height: 2000 mm.
  • Maximum vent height: 4500 mm.
  • Minimum vent width: 1000 mm.
  • Maximum vent width: 3000 mm.
  • Visible vent width: 25 mm.
  • Minimum interlock face width: 25 mm.
  • Minimum system basic depth: 107 mm.
  • Watertightness: Class 7A, 300 Pa.
  • Operating type: Manual.
  • Configuration: profiles, glazing or infill, hardware and interfaces are selected as one coordinated system.
  • Verification: final dimensions and performance are checked for the actual project arrangement.
  • Documentation: approved details are transferred into production and installation information.

Design, Performance and Application

Schüco AS PD 39.NI constructions are governed by panel dimensions, glass weight, track geometry, rollers, interlocks, handles and threshold design. Alumproof develops the configuration as one coordinated assembly. The number of tracks, opening direction, fixed and moving panels and required clear opening are established before profile and hardware selection.

Minimal sightlines require accurate control of tolerances and deflection. Glass thickness and weight affect the running gear, while panel proportions influence operation and weather performance. For lift-and-slide, standard sliding, panorama or folding configurations, the permissible element size must be confirmed from the applicable Schüco documentation and the selected hardware variant rather than inferred from a different typology.

The threshold and drainage concept are critical at the interface between interior and exterior levels. Recessed tracks may improve visual continuity but need coordinated waterproofing, outlets, maintenance access and external surface falls. Barrier-free aspirations must be reconciled with exposure, rainfall, wind pressure and the project-specific risk of water ingress. Head and jamb fixings must also allow the frame to remain straight under building movement and installation loads.

Thermal, acoustic, air, water and wind classifications refer to tested element configurations. Final results vary with panel size, glass, interlock, threshold and opening arrangement. Alumproof reviews these dependencies and prepares production information covering profile machining, drainage, hardware positioning, glazing blocks, assembly sequence and installation interfaces.

Glazing, Infill and Interfaces

Glazing or opaque infill is selected for safety, thermal, acoustic, structural and visual requirements. The nominal capacity of a profile does not by itself confirm that a proposed glass build-up is suitable. Alumproof checks thickness, weight, edge cover, support, compatibility with gaskets and sealants, and the influence of the infill on the element hardware and frame. Where panels, back pans, membranes or insulation are included, their interfaces are documented as part of the complete construction.

Connections to concrete, steel, timber, roofing, insulation, waterproofing and internal finishes are developed around the actual opening and substrate. Particular attention is given to fixing access, edge distances, drainage paths, membrane continuity, movement, tolerances and replaceability. These details help preserve the intended performance of Schüco AS PD 39.NI after the element leaves the factory.

From Drawings to Production

The design conversation around Schüco AS PD 39.NI normally moves from appearance to function and then to buildability. We compare the required opening or grid with the system limits, resolve the glass and hardware concept and develop junctions that can be manufactured and installed without losing the original architectural idea.

Alumproof reviews drawings, elevations, schedules and specifications before preparing production documentation. The review covers dimensions, opening logic, profile selection, component availability, machining access, hardware positions, drainage, glazing sequence, transport size and installation access. Questions that can affect cost or feasibility are raised before fabrication rather than being transferred to the construction site.

Approved profiles are cut and CNC-machined according to the production information. Assembly and glazing follow the selected system configuration, with checks appropriate to the product type and agreed quality plan. Finished elements are identified, protected and packed for coordinated delivery. Installation responsibilities, lifting conditions and site tolerances should be confirmed separately for each project.

Why Specify Schüco AS PD 39.NI Through Alumproof?

Alumproof combines architectural understanding with practical aluminium fabrication. This makes it possible to compare system variants, identify dimensional or interface risks, develop buildable details and maintain a direct connection between approved drawings and production. The objective is a technically coherent result that supports the architecture and can be manufactured, transported, installed and maintained as planned.

Related Alumproof Resources

Important System Note

All technical values, classifications and dimensional limits must be verified for the final Schüco AS PD 39.NI configuration. Actual performance depends on element size and proportions, selected profile variant, glazing or panel, hardware, seals, drainage, reinforcement, fixings, installation substrate and workmanship. A value published for one tested specimen or best-performing configuration must not be applied unconditionally to another construction.

Send your drawings, elevations, schedules or specification to Alumproof for a technical review and project quotation.